1Insufficienair pressure; 2 Wrong the gas channel selection 3. The solenoid valve is damage, or no control voltage output.
1Check the gas line pressure; 2.Check air channels is correct in the process parameters; 3.Check the solenoid valve, and associated circuitry;
abnormal sound for axis running
1. NO lubricating oil of axismotion components ; 2. The moving parts have to interfere with the fixed compensation items;
1. Add the oil;Check running path security of the moving parts running security
No laser or laser power shortage
1.NC signal is not sent; 2. lens is dirty or damaged; 3. The nozzle is damaged or blocked; 4 The optical path is incorrect 5. The laser alarms
1. Check the connection between CNC laser machine console ; 2. Check the protective lens; 3. Replace the nozzle; 4. Adjust the laser path 5. May water cooling machine temperature is too low, until the temperature reaches the requirement to restart the laser machine.
Cutting is not the same size with graphics and drawings
1. Program input errors; 2.The positioning accuracy influence; 3. The servo motor is damage; 4.The servo drive is damaged
1. Check the program; 2. Detection of precision machine tools; 3. Check the servo motor and servo feed drives if damaged, please replace them
inductive head alarms
1. amplifiers cable is loose . 2. The nozzle is loose, or ring loose. 3. System Problems The nozzle is damaged, or has iron slag。
1. Fastening 2. Fastening 3. recalibration Floating 4. Replace or clean the nozzles
Motor alarms
1.motor without electricity 2 .Motor alarms
1. Motor energized, disarm the alarm Check servo drive alarm information (see Table 1), to restart the motor power can disarm the alarm. Such as repeated alarm, please contact us.